Installation methods of LED display screen
LED display screen products are currently used in many fields in the market. According to the different application fields and installation environment, the installation methods of LED display screen are also different. Arrange a set of LED display installation methods for everyone to learn and reference. This time, we will mainly introduce six common installation methods, including suspension, floor, embedded, column, support and wall mounting
weak current intellectualization | full introduction to the installation methods and methods of LED display in weak current engineering
1, hanging
full introduction to the installation methods and methods of LED display in weak current intellectualization | weak current engineering
1) this installation method is mostly used indoors and semi outdoors
2) it is generally used at the entrance of channels and corridors, as well as stations, railway stations, subway entrances, etc.
3) it is used for highways, railways It is used for traffic guidance on highways
4) the design of the screen body generally adopts the design of an integrated cabinet, or the design of the hoisting structure
2. The inlaid installation method
the intelligent weak current can be removed sensitively | full introduction to the installation methods and methods of the LED display screen in weak current engineering
1) the whole LED display screen body is embedded in the wall, The display plane is on the same horizontal plane as the wall
2) simple box design is generally adopted
3) front maintenance (front maintenance design)
4) this installation method is used indoors and outdoors, but it is generally used with small spacing and small display area
5) generally used in building doorways, building halls, etc.
3, column type (single column and double column)
weak current intelligent | weak current engineering LED display installation methods and methods full introduction
weak current intelligent | weak current engineering LED display installation methods and methods full introduction
column type installation methods, Generally used for outdoor billboards:
1) single column installation method: suitable for small screen applications
2) double column installation method: suitable for large screen applications
3) closed maintenance channel: suitable for simple boxes
4) open maintenance channel: suitable for standard boxes
4 Wall mounted installation method
weak current intellectualization | full introduction to the installation methods and methods of LED display screen in weak current engineering
1) this installation method is usually used indoors or semi outdoors
2) the display area of the screen is small, and generally there is no maintenance channel space. The whole screen is removed for maintenance, or it is made into a folding integrated frame
3) the screen area is slightly larger, Generally, the front maintenance design is adopted (that is, more and more new composite materials in the front dimension are used in the manufacture of body in white and sunroof protection design, and the column assembly method is often adopted after inquiry and discussion)
5. Roof installation
weak current intelligence | full introduction to the installation methods and methods of LED display screen in weak current engineering
1) this installation method is the key to the wind resistance of display screen and steel frame structure
2) it is generally installed at an inclined angle, Or the module adopts an oblique 8 ° design
3) it is mostly used for outdoor advertising display
6. Leasing and hoisting methods
weak current intellectualization | full introduction to the installation methods and methods of LED display in weak current engineering
precautions:
hoisting screen should not be made large. Generally, it is required to be below 6m*10m. Exceptions to special box materials and strip curtain type
the top is equipped with a lifting beam, and the bottom is equipped with a bottom beam. The lifting beam is used to lift the screen
the row and row boxes are connected by a lifting mechanism, and the horizontal boxes are fastened by a lock catch
hoisting mechanism is divided into gear type, taper rod type and bolt type
has the following different characteristics:
1 Gear type is more expensive and beautiful,
2 The taper rod type is moderate in price and reliable
3. Bolt type * is cheap, reliable, and troublesome to assemble. It is suitable for the situation without repeated disassembly and assembly
in the installation of real projects, there are other installation methods, which will not be introduced here. These six kinds of installation methods are relatively common, and the installation difficulty is relatively small* The main thing is to require the installation personnel to strictly implement the installation operation process to ensure the qualified and safe installation of the screen. Only in this way can the communication effect of the LED display screen be truly brought into play and meet the requirements of advertisers
LINK
Copyright © 2011 JIN SHI