Installation method of ion fan
the function of ion fan is to ionize the air with electrostatic generator to generate a large number of positive and negative charges, and use ion fan to blow out the positive and negative charges. A stream of positive and negative charges is formed to neutralize the charges on the surface of the object. When the surface of the object is negatively charged, it will attract the positive charge in the air flow. When the surface of the object is positively charged, it will attract the negative charge in the current, so that the static electricity on the surface of the object can be neutralized. The purpose of eliminating static electricity can be achieved by stretching, tightening, bending, peeling, puncturing and other experiments in all materials within 30000N
in industrial production, due to the friction, peeling, extrusion, induction, etc. between objects, the surface area of objects has different charges. When this charge accumulates to a certain extent, electrostatic adsorption and discharge will occur. The accumulation and discharge of electrostatic charges will cause great impact and damage to industrial production. For example, adhesion, repulsion, electrostatic breakdown, human shock, explosion, etc
installation method of ion fan
a. installation of desktop ion fan
place the desktop ion fan on the table or hang it above the table, plug in the power supply, and turn on the fan. Adjust the air flow of the fan to the required working area, and tighten the fastening nuts on both sides of the fan to start working
b, installation of suspended ion fan
hang the suspended ion fan at an appropriate height, adjust the air volume and direction to the required position, and then start working
c installation of horizontal ion fan
place the horizontal ion fan on the table, plug in the power supply, turn on the ion fan, adjust the air flow of the ion fan to the required working area, and tighten the fastening nuts on both sides of the fan to start working. The horizontal ion fan can also be suspended
if you use an ion fan in a particularly dirty environment, you can choose to install a filter
operation of ion fan
turn the governor switch clockwise until the indicator light is on, then turn on the ion fan to generate ion airflow and increase the fan wind speed. Rotate the governor switch clockwise; Rotate the governor counterclockwise to the off position, and the indicator light is off, indicating that the ion fan is off
when adjusting the air flow direction, loosen the plum blossom screws of the support, tilt the machine body to adjust the upper and lower positions, and tighten the support screws after adjustment
when ionic wind needs to be heated, turn on the heating switch to heat the ionic wind blown out by the fan; Turn on the light switch when you want the light (some models have no hot air and lighting functions)
maintenance of ion fan
cleaning of emitter head, adjustment and correction of ion balance, and correction of electrostatic removal time to ensure the normal operation of ion fan
a, cleaning of the transmitter
clean the emission point of the transmitter, slide or rotate the cleaning brush left and right until the tip of the net ion emission needle is cleaned, at least once a week
b, cleaning of air inlet and outlet
the equipment parameter port and ionized air outlet of the air inlet spring fatigue life testing machine should be cleaned to prevent blocking the air flow, which can be cleaned with a soft brush or compressed air
c, test of ion balance and residual electrostatic voltage
it is recommended to use SIMCO fmx-003 electrostatic tester or 3M 718718a ion fan tester
d, electrostatic elimination time test
to measure the electrostatic elimination time. It is recommended to use manual 268a flat electrostatic tester
e, Jinan gold assay hardness testing instrument series of ion fan on ion quantity: mechanical Rockwell hardness tester, plastic Rockwell hardness tester Digital display Rockwell hardness tester, Leeb hardness tester, surface Rockwell hardness tester, full Rockwell hardness tester, Vickers hardness tester, low load Vickers hardness tester, digital display micro Vickers hardness tester, image processing micro Vickers hardness tester, Brinell hardness tester, low load Brinell hardness tester, bulloway hardness tester, Shaw hardness tester, shore hardness tester, portable Rockwell hardness tester, Vickers hardness tester, Babbitt hardness tester The output design of tube Rockwell hardness tester is balanced and fixed. Because it may be affected by voltage fluctuations, ambient air humidity and other factors, it will form the following performance requirements for the materials used: the shift of ion balance [residual voltage]. Offset standard: ov 10V. If there is a large deviation between the static elimination time and the residual voltage, it should be sent to the factory for calibration